Labour accommodation is one of the categories where the national surveillance manual marks the control room, ANPR and AI video analytics as mandatory. This guide sets out what Version 3.0 (2026) says for operators in Mussafah and across Abu Dhabi, what depends on the site, and where to confirm with the authority.

Short answer

What does the manual require for labour accommodation?

Short answer: labour accommodation is a named category (Group A) with 90 days of storage, and a monitoring and control room, ANPR and AI video analytics are all marked Mandatory. ANPR applies only where the facility has a designated parking area. Only licensed entities may design, install, operate and maintain the system, and the authorities can add or change requirements.

PointMCC V3.0 for labour accommodation
CategoryCategory 22 in the manual's table, Group A
DefinitionAny building or group of buildings designated to accommodate workers on a permanent or temporary basis and licensed under the applicable regulations
Storage period90 days (the authorities may set longer; minimum 30 days); storage with at least 20% spare capacity
Monitoring and control roomMandatory
ANPRMandatory, but only where the facility has a designated parking area
AI video analyticsMandatory
Named coverage areasLaundry room and training room at recognition level, plus the general mandatory areas in section 3.1

Compare with other categories in the full summary: UAE surveillance system requirements 2026 (MCC V3.0). Existing camp operators can also see our labour accommodation camp IT and CCTV page.

Not sure which requirements apply to your premises?

Tell us your licensed activity and location. We survey free of charge, explain what the manual may mean for your site, and list what to confirm with the authority. We reply the same working day.

Coverage

Areas to cover at an accommodation site

The manual names only two areas for this category (laundry room and training room, both recognition level). The general list in section 3.1 supplies the rest, wherever those places exist. Confirm with the authority which apply to your layout.

Coverage levelGeneral mandatory areas that commonly exist in an accommodation site (section 3.1)
IdentificationEntrances and exits of the facility; emergency exits; control rooms and main equipment racks; cash handling or selling points and safes, if present
RecognitionEntrances of main utility rooms from outside; entrances of public toilets from outside; lobbies, receptions and waiting areas; lift lobbies, lifts and stairs; corridors; goods loading and unloading areas; public praying areas; main kitchens, dining and canteen areas; laundry room and training room (named for this category); gas cylinder storage areas
ObservationBuilding perimeter from outside; ramp entries and exits; emergency assembly areas; indoor and outdoor play areas and public pools, if present
DetectionLandscape areas; parking areas
Vehicle view / plate readingEntrances and exits of vehicles; passenger drop-off and pick-up entrances and exits

Sleeping quarters are not named among the mandatory or optional areas in section 3. Treat them as private areas: the manual requires prior approval for cameras whose view exposes private or restricted areas, so confirm with the authority before any camera is placed near them. Optional operational coverage (store rooms, maintenance rooms, security cabins, back-of-house areas and similar) can be added where needed.

Control room

Control room, ANPR and AI: what mandatory means in practice

Mandatory means the control room rules in section 2 apply: access limited to staff, operators and authorised visitors with an entry and exit log; no camera-equipped devices inside; door access control and cameras in the room; a dedicated hotline to the competent authorities; and at least 30 minutes of backup power. See control room design.

ANPR applies where there is a designated parking area or vehicle gate: fixed IP ONVIF Profile S cameras, IP66, at least 1920 x 1080, 25 fps (PAL) or 30 fps (NTSC), infrared, at least 99% vehicle detection and 98% plate recognition for GCC plates, CSV reports and six alert types. See ANPR installation in Abu Dhabi.

AI video analytics must run on the surveillance network only, keep events and metadata on premises, reach at least 90% detection accuracy, and support AES-256, TLS 1.2 or higher, RBAC and multi-factor authentication for administrators. The manual has no analytics list specific to labour accommodation, so the general table for all categories applies: face detection and people counting at main entrances; motion detection at control rooms, racks and restricted areas; intrusion at emergency exits and the perimeter; loitering on staircases; violent behaviour, slip and fall, dangerous objects and crowd detection in lobbies, reception and waiting areas and dining areas; fire detection and wrong-way driving in parking areas; unauthorised parking at drop-off areas; and camera tampering at main entrances, emergency exits and control rooms. See AI video analytics.

Practical points

What this means for design, storage and maintenance

The points below are Emirtech's practical reading, not extra manual requirements.

  • Storage is the big number: 90 days of recording plus at least 20% spare, across every camera, grows quickly on a large site. Storage is sized from camera count, resolution, codec and frame rate; see CCTV storage sizing.
  • More than two recorders: a Group A clause says they must be managed through a central management system.
  • Long corridors, stairs and canteens: recognition level is 125 px/m at 12 fps, so coverage is planned by distance, not just by count.
  • Entrances: identification level needs 500 px/m at 25 fps and a shallow incidence angle, so entrance cameras are aimed for faces.
  • Network and security: the surveillance network must be dedicated and isolated, with named accounts, no public internet exposure and no cloud use without prior approval.
  • Maintenance: the manual asks for an annual maintenance contract with a company registered by the concerned authorities, faults reported and solved within one working day, periodic camera cleaning and records. See CCTV AMC in Abu Dhabi.
  • Signage and documents: signs in Arabic, English and Urdu, DWG drawings with colour-coded levels, and an up-to-date document set.

Local context

Accommodation sites in Mussafah and Abu Dhabi

Emirtech is based at M44, Mussafah Industrial Area, so accommodation sites in Mussafah, ICAD, KIZAD and nearby areas are quick for us to visit, and we also work across Abu Dhabi. The survey starts by confirming whether the site is licensed as labour accommodation, where the parking and vehicle gates are, and where a control room can sit. We do not decide your category or licensing status; the authority does. See CCTV installation in Mussafah and gate barriers in Mussafah.

Answers

Frequently asked questions

Is CCTV mandatory for labour accommodation in Abu Dhabi?
Labour accommodation is a named category in the national manual with a 90-day storage period, a mandatory control room, mandatory ANPR (where there is a designated parking area) and mandatory AI video analytics. The authorities decide how it applies to your licence.
Is ANPR required for a labour camp?
The table marks ANPR Mandatory for labour accommodation, but the manual says the ANPR requirement applies only where the facility has a designated parking area.
How long must labour accommodation CCTV footage be stored?
90 days in the table. The authorities may set a longer period; the minimum is 30 days. Storage must also include at least 20% spare capacity.
Which areas must be covered in labour accommodation?
The manual names the laundry room and training room (recognition level) for this category, and the general mandatory areas in section 3.1 apply where they exist, such as entrances and exits, corridors, lifts and stairs, canteens, the perimeter and parking.
Can I put cameras in sleeping rooms?
Sleeping quarters are not listed as mandatory or optional coverage areas, and cameras that expose private or restricted areas need prior approval from the concerned authorities. Confirm before placing any camera.
Does Emirtech certify that my accommodation complies?
No. Emirtech is an installer and integrator, not the MCC or a certification body. We survey, install, upgrade and maintain systems; approval and interpretation belong to the concerned authorities.

Request a survey

Discuss your commercial surveillance project

Free site survey, CCTV installation quotation, ANPR consultation, AI video analytics assessment, CCTV upgrade or AMC proposal. We reply the same working day.

We reply the same working day. Your details are used only to answer your enquiry.

Prefer to talk? Call +971 55 651 7843 or message us on WhatsApp for your location:

Source and limits

Source: National Manual for Surveillance Systems, Version 3.0, 2026 (Monitoring and Control Centre): section 4 category table and notes, section 3 items 1.1 and 2.19, section 2 monitoring room clauses, and sections 4 and 5. The authorities can change the manual and its requirements, and the Arabic text is authentic if it differs. This is a summary, not legal advice. Emirtech is not the MCC or a government body, holds no SIRA registration and does not guarantee approval. Reviewed 24 November 2026.

Need a free site survey or quote in Abu Dhabi?

Talk to Emirtech's engineers — we reply the same working day across Abu Dhabi and Al Ain. CCTV, security, IT, AV and smart-building solutions.

Mon–Sat 8AM–7PM · [email protected] · Since 2018 · ADMCC-approved for security systems